2.
Measurement Process Characterization
2.3. Calibration 2.3.4. Catalog of calibration designs 2.3.4.3. Designs for electrical quantities
|
|||
Design 1,1,1,1,1,1
CELLS OBSERVATIONS 1 1 1 1 1 1 Y(1) + - Y(2) + - Y(3) + - Y(4) + - Y(5) + - Y(6) + - Y(7) + - Y(8) + - Y(9) + - Y(10) - + Y(11) - + Y(12) - + Y(13) + - Y(14) + - Y(15) + - RESTRAINT + + + + + + DEGREES OF FREEDOM = 9 SOLUTION MATRIX DIVISOR = 6 OBSERVATIONS 1 1 1 1 1 1 P Y(1) 1 -1 0 0 0 0 1 Y(2) 1 0 -1 0 0 0 1 Y(3) 0 1 -1 0 0 0 1 Y(4) 0 1 0 -1 0 0 1 Y(5) 0 0 1 -1 0 0 1 Y(6) 0 0 1 0 -1 0 1 Y(7) 0 0 0 1 -1 0 1 Y(8) 0 0 0 1 0 -1 1 Y(9) 0 0 0 0 1 -1 1 Y(10) -1 0 0 0 1 0 1 Y(11) -1 0 0 0 0 1 1 Y(12) 0 -1 0 0 0 1 1 Y(13) 1 0 0 -1 0 0 1 Y(14) 0 1 0 0 -1 0 1 Y(15) 0 0 1 0 0 -1 1 R* 1 1 1 1 1 1 0 R* = AVERAGE VALUE OF 6 REFERENCE CELLS P = LEFT-RIGHT BIAS FACTORS FOR COMPUTING STANDARD DEVIATIONS V FACTOR CELLS 1 1 1 1 1 1 1 0.3727 + 1 0.3727 + 1 0.3727 + 1 0.3727 + 1 0.3727 + 1 0.3727 + | |||
Explanation of notation and interpretation of tables |