2.
Measurement Process Characterization
2.3. Calibration 2.3.4. Catalog of calibration designs 2.3.4.2. Drift-elimination designs for gage blocks
|
|||
CAMERON-HAILES DESIGN FOR 6 GAGE BLOCKS + DRIFT
OBSERVATIONS 1 1 1 1 1 1
Y(1) + -
Y(2) + -
Y(3) + -
Y(4) + -
Y(5) - +
Y(6) - +
Y(7) + -
Y(8) - +
Y(9) + -
Y(10) - +
Y(11) + -
Y(12) - +
Y(13) - +
Y(14) - +
Y(15) - +
Y(16) - +
Y(17) + -
Y(18) + -
RESTRAINT + +
CHECK STANDARD + -
DEGREES OF FREEDOM = 12
SOLUTION MATRIX
DIVISOR = 4728
OBSERVATIONS 1 1 1 1 1 1 Drift
Y(1) 689 -689 31 111 -79 25 -17
Y(2) -360 360 -1320 -456 -144 -912 -15
Y(3) -40 40 904 -576 -16 424 -13
Y(4) 43 -43 -499 501 -101 -1165 -11
Y(5) 52 -52 716 276 -452 1340 -9
Y(6) -384 384 168 144 792 288 -7
Y(7) 3 -3 405 -75 -117 -741 -5
Y(8) -289 289 385 921 239 463 -3
Y(9) -305 305 -199 -255 -713 -313 -1
Y(10) -3 3 -405 75 117 741 1
Y(11) 289 -289 -385 -921 -239 -463 3
Y(12) 305 -305 199 255 713 313 5
Y(13) -95 95 -217 -777 553 -175 7
Y(14) -3 3 -405 75 117 741 9
Y(15) 400 -400 416 1032 160 488 11
Y(16) -329 329 1289 345 223 887 13
Y(17) -305 305 -199 -255 -713 -313 15
Y(18) 384 -384 -168 -144 -792 -288 17
R* 2364 2364 2364 2364 2364 2364 0
R* = Sum of the two reference standards
FACTORS FOR REPEATABILITY STANDARD DEVIATIONS
NOM FACTOR
1 1 1 1 1 1
1 0.2699 +
1 0.2699 +
1 0.5253 +
1 0.4545 +
1 0.3989 +
1 0.5890 +
0 0.5399 + -
Explanation of notation and
interpretation of tables
| |||